Skip to content

EMI, EMC and ESD

Common-Mode vs Differential-Mode Noise

Ten microamps of common mode can out-radiate ten milliamps of differential mode. The loop is the reason.

  • Lesson 3 of 3
  • Advanced

6 min read

Here is a comparison that reorders most people's intuition about EMC.

A one square centimetre loop carrying ten milliamps at 100 MHz produces about 44 µV/m at three metres. A one metre cable carrying ten microamps of common-mode current at the same frequency produces about 420 µV/m at the same distance.

A thousandth of the current, ten times the field. If you only remember one thing from this course, make it that.

Quick answer. Differential-mode current goes out on one conductor and back on the other, so the loop it encloses is the gap between them, which is small. Common-mode current goes out on all conductors together and returns through the ground, the earth or stray capacitance, so the loop it encloses is the whole installation. Same current, vastly different loop, vastly different radiation.

The two patterns

In differential mode the current goes out on one conductor and back on the other, and the loop it encloses is the gap between them. In common mode it goes out on all of them at once and returns through the environment, so the loop is the whole installation.
Figure 1. The mode does not change the current: it changes the area it encloses.

Differential mode is the current you designed. It leaves on the signal or supply conductor and returns on its partner. The area enclosed is the area between the two conductors, which in a twisted pair or a trace over a plane is tiny. This is also the mode that carries your actual information or power.

Common mode is current flowing in the same direction on every conductor of a cable at once. It has to return somewhere, and the only place left is through whatever capacitance exists between the far end of the system and the reference. The loop is therefore the physical area enclosed by the cable, the equipment at both ends and the return path through the environment. It can be square metres.

Common mode carries no information. It is pure parasitic, which means that unlike differential mode you can attack it without damaging anything you wanted.

The arithmetic behind the comparison

Both fields are calculable with standard small-source relations, which is what makes the comparison honest rather than rhetorical.

For a small loop, the field at distance r:

E = 1.316×10⁻¹⁴ · f² · A · I / r

with f in hertz, A in square metres, I in amps and r in metres. For a 1 cm² loop carrying 10 mA at 100 MHz, measured at 3 m:

E = 1.316×10⁻¹⁴ × (10⁸)² × 10⁻⁴ × 0.01 / 3 = 4.39×10⁻⁵ V/m = 44 µV/m

For a cable carrying common-mode current, treated as a short dipole:

E = 1.26×10⁻⁶ · f · I · L / r

For 10 µA on a 1 m cable at 100 MHz, at 3 m:

E = 1.26×10⁻⁶ × 10⁸ × 10⁻⁵ × 1 / 3 = 4.2×10⁻⁴ V/m = 420 µV/m

Note the different frequency dependence. The loop field goes as f², the cable field as f. That is not a contradiction: they are different radiating structures, one electrically small in both dimensions and one long. What they share is that the field is proportional to the current and to the size.

Two things follow directly:

  • Doubling the loop area adds 6 dB. The relation is linear in A.
  • Doubling the frequency adds 12 dB to a loop and 6 dB to a cable. Which

is why harmonics matter so much more than the fundamental, right up until the harmonic currents themselves fall away.

Where common-mode current comes from

Nobody designs it. It appears from asymmetry, and the three usual sources are worth knowing by name because each has a different fix.

  • A voltage difference between two grounds. If the board's reference and

the far end's reference are not at the same potential at that frequency, the difference drives current along every conductor between them equally. This is the most common source and it is a layout problem.

  • Capacitive coupling from a noisy node. A switch node or a heatsink at a

high dV/dt couples displacement current into whatever is nearby, including cables, and that current has nowhere to return except through the environment.

  • Imbalance in a differential pair. If the two halves of a pair are not

electrically identical, some of the differential signal converts into common mode. This is mode conversion, and it is why skew and asymmetry in a pair matter beyond timing.

Telling them apart before trying to fix them

This is the single highest-value diagnostic step in an emissions investigation, because the remedies for the two modes are almost disjoint.

ObservationSuggests
Emissions change a lot when a cable is moved or coiledcommon mode
A clamp-on current probe around the whole cable reads currentcommon mode
A clamp around the whole cable reads nothing, around one conductor reads a lotdifferential mode
A ferrite sleeve over the whole cable helpscommon mode
The problem is at the switching frequency and low harmonics on the supplylikely differential
Touching the enclosure or adding an earth strap changes thingscommon mode

The current probe test is decisive and cheap. A clamp around all the conductors of a cable sums the currents, so differential components cancel and only common mode is left. If that reads significant current at the frequency you are failing, you have your answer and half the possible remedies are eliminated.

The remedies are different

Differential mode responds to loop area, to filtering between the conductors, and to reducing the current itself. A capacitor across the pair attacks it.

Common mode responds to breaking the common-mode loop: a common-mode choke, a ferrite over the whole cable, a capacitor from each conductor to the reference rather than between them, better bonding between the two ends, or removing the asymmetry that created it.

Applying a differential remedy to a common-mode problem is the classic way to spend a week changing nothing. A capacitor between the two conductors of a pair is invisible to a current flowing the same way in both.

What comes next

Lesson 4 takes the first of the two relations above and works it properly: what loop area really costs, where the loops on a typical board actually are, and why the cheapest decibels in any design are in the layout.

Sources and further reading

Where to go next

EMC and EMI

Conducted vs Radiated Emissions

Thirty megahertz is not an arbitrary line. It is where a cable stops being a wire and becomes an antenna.

¿Te ha resultado útil?

Reddit LinkedIn

The XKEMA newsletter

Hardware engineering worth keeping

New courses, engineering notes and hardware guides, whenever there is something genuinely worth reading. Nothing else.

We will email you to confirm. You can unsubscribe from any issue.

XKEMA, in one sentence

Engineering knowledge management software for companies that develop electronic products: the product structure, its bills of materials, its documentation and its revisions, all in one place.