Conducted vs Radiated Emissions
Thirty megahertz is not an arbitrary line. It is where a cable stops being a wire and becomes an antenna.
- Lesson 2 of 2
- Advanced
Emissions get measured twice, in two frequency ranges, by two completely different methods. Below about thirty megahertz the measurement is made on the power cable with a network; above it, with an antenna across a room.
The boundary is not a committee's convenience. It is where the things in the room stop being small compared with a wavelength.
Quick answer. Conducted emissions are noise currents leaving on the cables, measured with a line impedance stabilisation network, typically from 150 kHz to 30 MHz. Radiated emissions are fields leaving through the air, measured with an antenna at a stated distance, typically from 30 MHz upwards. The split is at 30 MHz because that is where a metre or two of cable becomes an efficient antenna.
Where 30 MHz comes from
A conductor radiates efficiently when its length is a meaningful fraction of the wavelength, with a quarter wave being the usual reference point. So work out the quarter wave at a few frequencies:
λ = c / f| Frequency | Wavelength | Quarter wave |
|---|---|---|
| 30 MHz | 10 m | 2.5 m |
| 100 MHz | 3 m | 0.75 m |
| 300 MHz | 1 m | 0.25 m |
| 1 GHz | 0.3 m | 0.075 m |
Read that table as a sequence of statements about what is an antenna.
At 30 MHz you need two and a half metres to resonate, which is a long mains lead but not a typical signal cable. Below that, almost nothing attached to a product is an efficient radiator, so the energy stays on the wires and is best caught by measuring current on the wires.
At 100 MHz, seventy-five centimetres resonates. That is an ordinary USB cable, a sensor lead, a ribbon between two boards. This is the band where cables dominate radiated emissions and where the fix is almost always to stop common-mode current getting onto them.
At 1 GHz, seven and a half centimetres resonates. Now a PCB trace is an antenna, a heatsink is an antenna, and a slot in a plane is an antenna. The problem has moved from the cables onto the board itself.
The lesson is not the number 30. It is that the frequency tells you what to suspect, because it tells you what is the right size.
What a conducted measurement actually does
A line impedance stabilisation network sits between the mains or supply and the product. It does two jobs: it presents a defined impedance to the product instead of whatever the building's wiring happens to be, and it provides a measurement port that sees the noise current the product is pushing out.
That first job is the important one to understand. Without it, the same product measured in two laboratories would give two different answers, because the impedance of the supply is part of the circuit. Standardising it is what makes the measurement a measurement.
Two consequences for design:
- The result depends on the impedance seen at the port, which is defined
by the network, not by your bench supply. A product that is quiet on your bench can be loud in the laboratory purely because the source impedance is different.
- Both the live and return conductors are measured, so noise that goes out
on one and back on the other and noise that goes out on both are both visible, but they are not the same problem. Lesson 3 is about telling them apart.
What a radiated measurement actually does
An antenna at a stated distance, in an environment whose reflections are either absorbed or known, sweeping the frequency range and recording the field strength.
The things that surprise people are all about the setup rather than the product:
- Cable routing changes the result, often by several decibels, because the
cable is the antenna and you have just changed its shape.
- Orientation matters, which is why the product is rotated and the antenna
height is scanned: you are looking for the worst case, not a typical one.
- The distance is part of the specification. A field falls with distance,
so a measurement at three metres and one at ten metres are not comparable without the correction, and the correction is not always a simple one.
The same energy, two views
A single mechanism can show up in both measurements. A switching converter pushing current back onto its input produces conducted emissions directly. If that same current continues out along the supply cable, the cable radiates it, and the same mechanism appears in the radiated measurement at the frequencies where the cable is a decent antenna.
This is why a filter that fixes a conducted problem sometimes fixes a radiated one too, and why it sometimes does not. If the energy is reaching the cable conductively, filtering the cable helps both. If it is coupling onto the cable by a field from somewhere else on the board, filtering the cable does nothing for the radiated result because the energy is joining the cable past the filter.
That distinction, between energy that arrives at the cable through the copper and energy that arrives at it through the air, is one of the most useful diagnostic questions in EMC. If a filter at the connector improves the conducted result and leaves the radiated result unchanged, you have your answer.
What this changes about where you look
| Symptom | Frequency | Look at |
|---|---|---|
| Conducted peak at the switching frequency and its low harmonics | 150 kHz to a few MHz | the converter's input loop and filter |
| Conducted limit exceeded broadly across the band | up to 30 MHz | common-mode current on the supply pair |
| Radiated peak at a clock harmonic | 30 to 300 MHz | cables, and what is driving them |
| Radiated problem that moves when a cable is moved | 30 to 300 MHz | common-mode current on that cable |
| Radiated problem above 500 MHz, cables irrelevant | above 500 MHz | the board: traces, slots, heatsinks |
What comes next
Lesson 3 takes the single most useful distinction in the whole subject: the difference between noise that goes out and comes back on your own conductors, and noise that goes out on all of them at once.
Sources and further reading
- Texas Instruments: AN-2162 Simple Success With Conducted EMI from DC-DC Converters (SNVA489) — application report, the conducted measurement setup, the stabilisation network and what it standardises.
- Texas Instruments: PCB Design Guidelines For Reduced EMI (SZZA009) — application report, what radiates at which frequency and why size decides.
- Microchip: AN2587 EMI, EMC, EFT and ESD Circuit Design Considerations — application note, the measurement categories and the design responses to each.
- Texas Instruments: High-Speed Layout Guidelines (SCAA082) — application report, why board features become radiators as frequency rises.
- Keysight: N6141A & W6141A EMI X-Series Measurement Application (5990-6035) — technical overview, the CISPR 16-1-1 detectors and bandwidths, and the difference between a precompliance measurement and a test-house one.